Paper Abstract and Keywords |
Presentation |
2015-02-19 15:05
SAR evaluation for human body with implanted medical devices during MR imaging Mahito Koizumi, Kazuyuki Saito, Koichi Ito (Chiba Univ.) |
Abstract |
(in Japanese) |
(See Japanese page) |
(in English) |
Modern MRI systems employ high-frequency and high-powered radio frequency (RF) pulses. Given this, it is necessary to evaluate the specific absorption rate (SAR) of the irradiated human body. Recently, the materials and shapes of implantable medical devices such as artificial joints or pacemakers have become increasingly diverse. At once, making it more likely that subjects’ implanted medical devices will potentially causing temperature increases in unexpected regions. Therefore, in order to consider the safety of patients with implanted medical devices during MR imaging, it is necessary to comprehend the detailed SAR distribution within the human body. In this study, we evaluated SAR for human body with carotid stent and DBS as one example of medical devices during MR imaging. In these results, SAR value increased around these devices. However, these values were below safety guideline sufficiently. |
Keyword |
(in Japanese) |
(See Japanese page) |
(in English) |
Specific Absorption Rate (SAR) / Magnetic Resonance Imaging (MRI) / carotid stent / Deep Brain Stimulation (DBS) / / / / |
Reference Info. |
ITE Tech. Rep., vol. 39, no. 6, BCT2015-28, pp. 13-16, Feb. 2015. |
Paper # |
BCT2015-28 |
Date of Issue |
2015-02-12 (BCT) |
ISSN |
Print edition: ISSN 1342-6893 Online edition: ISSN 2424-1970 |
Download PDF |
|
Conference Information |
Committee |
BCT IEEE-BT |
Conference Date |
2015-02-19 - 2015-02-20 |
Place (in Japanese) |
(See Japanese page) |
Place (in English) |
|
Topics (in Japanese) |
(See Japanese page) |
Topics (in English) |
|
Paper Information |
Registration To |
BCT |
Conference Code |
2015-02-BCT-BT |
Language |
Japanese |
Title (in Japanese) |
(See Japanese page) |
Sub Title (in Japanese) |
(See Japanese page) |
Title (in English) |
SAR evaluation for human body with implanted medical devices during MR imaging |
Sub Title (in English) |
|
Keyword(1) |
Specific Absorption Rate (SAR) |
Keyword(2) |
Magnetic Resonance Imaging (MRI) |
Keyword(3) |
carotid stent |
Keyword(4) |
Deep Brain Stimulation (DBS) |
Keyword(5) |
|
Keyword(6) |
|
Keyword(7) |
|
Keyword(8) |
|
1st Author's Name |
Mahito Koizumi |
1st Author's Affiliation |
Chiba University (Chiba Univ.) |
2nd Author's Name |
Kazuyuki Saito |
2nd Author's Affiliation |
Chiba University (Chiba Univ.) |
3rd Author's Name |
Koichi Ito |
3rd Author's Affiliation |
Chiba University (Chiba Univ.) |
4th Author's Name |
|
4th Author's Affiliation |
() |
5th Author's Name |
|
5th Author's Affiliation |
() |
6th Author's Name |
|
6th Author's Affiliation |
() |
7th Author's Name |
|
7th Author's Affiliation |
() |
8th Author's Name |
|
8th Author's Affiliation |
() |
9th Author's Name |
|
9th Author's Affiliation |
() |
10th Author's Name |
|
10th Author's Affiliation |
() |
11th Author's Name |
|
11th Author's Affiliation |
() |
12th Author's Name |
|
12th Author's Affiliation |
() |
13th Author's Name |
|
13th Author's Affiliation |
() |
14th Author's Name |
|
14th Author's Affiliation |
() |
15th Author's Name |
|
15th Author's Affiliation |
() |
16th Author's Name |
|
16th Author's Affiliation |
() |
17th Author's Name |
|
17th Author's Affiliation |
() |
18th Author's Name |
|
18th Author's Affiliation |
() |
19th Author's Name |
|
19th Author's Affiliation |
() |
20th Author's Name |
|
20th Author's Affiliation |
() |
Speaker |
Author-1 |
Date Time |
2015-02-19 15:05:00 |
Presentation Time |
25 minutes |
Registration for |
BCT |
Paper # |
BCT2015-28 |
Volume (vol) |
vol.39 |
Number (no) |
no.6 |
Page |
pp.13-16 |
#Pages |
4 |
Date of Issue |
2015-02-12 (BCT) |