Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
BCT, KYUSHU, IEEE-BT, IEEE-AP-S-FUKUOKA |
2022-01-21 11:20 |
Online |
Online |
Experimental Study on Phase Noise Improvement of 2nd-Harmonic Feedback Oscillator Using Active Ring Resonator Reou Kikuchi, Takayuki Tanaka, Ichihiko Toyoda (Saga Univ.) |
In this study, we propose a low phase noise 2nd-harmonic feedback oscillator. The proposed oscillator integrates an acti... [more] |
BCT2022-2 pp.5-8 |
BCT, IEEE-BT |
2022-02-17 11:10 |
Online |
TBD |
Development of simple structure wireless tag without ICs Toshinari Kobayashi, Kazuyuki Saito (Chiba Univ.) |
In current surgical operation, various medical devices are used and treatments are performed. Sometimes, used medical de... [more] |
BCT2021-9 pp.1-4 |
ME |
2019-07-16 10:30 |
Tokyo |
|
High resolution ultrasound imaging based on frequency sweep and array signal processing Ryoya Kozai, Nguyen Chi Hai, Jing Zhu, Norio Tagawa (Tokyo Metropolitan Univ.) |
Ultrasound imaging is widely used not only for medical applications but also for nondestructive testing and environmenta... [more] |
ME2019-83 pp.1-4 |
BCT, KYUSHU, IEEE-AP-S-FUKUOKA |
2019-01-24 14:30 |
Fukuoka |
Kyushu Sangyo Univ. |
Design of a passive harmonic transponder Naoki Matsunaga, Takuma Yamashita, Masahiko Nishimoto (Kumamoto Univ.) |
This paper describes design of a passive harmonic transponder for insect tracking and survivor detection. The transponde... [more] |
BCT2019-4 pp.13-16 |
BCT, KYUSHU |
2018-01-19 09:40 |
Nagasaki |
Nagasaki Univ. Unzen-E-Camllage-Kohryu-Center |
Basic Study of a Multi-Port Fourth-Harmonic Push-Push Oscillator Using a Ring Resonator Naoaki Takeda, Takayuki Tanaka, Ichihiko Toyoda (Saga Univ.) |
In this paper, a basic study of a multi-port fourth-harmonic Push-Push oscillator suitable for oscillator arrays is pres... [more] |
BCT2018-14 pp.53-56 |
ME, AIT, IEICE-IE [detail] |
2015-11-13 10:00 |
Kumamoto |
Sojo University Ikeda Campus |
Verification of high definition of low field MRI image using NHA Masaya Hasegawa, Shigeki Hirobayashi, Tadanobu Misawa (Toyama Univ.), Koichi Mori (Toyama Univ.Hospital), Kyo Noguchi (Toyama Univ.) |
In late years the MRI that is a tomogram technology using a magnetic resonance phenomenon attracts its attention. MRI ac... [more] |
|
ME |
2011-12-13 11:30 |
Kumamoto |
Kumamoto Univ. |
High S/N Ultrasound Tissue Harmonic Imaging Using Characteristics of Fundamental Echo Takuya Yamamura (Tokyo Metro. Univ.), Masayuki Tanabe (Kumamoto Univ.), Kan Okubo, Norio Tagawa (Tokyo Metro. Univ.) |
Tissue Harmonic Imaging (THI) is used for obtaining high spatial resolution medical ultrasound images. THI has a high ra... [more] |
ME2011-142 pp.43-46 |
HI [detail] |
2011-12-10 14:50 |
Okinawa |
Okinawa Industry Support Center |
Generation of the moire in the spatial frequency beyond threshold detection
-- Response for the banding by the single carrier with a single side band -- Koichiro Shinohara, Kazuho Fukuda, Keiji Uchikawa (TokyoTech) |
When jitter is attached to a regional screen beyond the visual spatial frequency response, banding (a transversal line) ... [more] |
HI2011-92 pp.81-84 |
BCT, KYUSHU, IEEE-AP-S-FUKUOKA, IEEE-BT-TOKYO |
2009-01-22 15:50 |
Fukuoka |
|
The 8th Harmonic V-Band Push-Push Oscillator using Slot Ring Resonator Yuki Yuge, Kengo Kawasaki, Takayuki Tanaka, Masayoshi Aikawa (Saga Univ.) |
This paper represents the eighth harmonic Push-Push oscillator. A both-sided MIC technology is adopted in the oscillator... [more] |
|