ITE Technical Group Submission System
Conference Schedule
Online Proceedings
[Sign in]
    [Japanese] / [English] 
( Committee/Place/Topics  ) --Press->
 
( Paper Keywords:  /  Column:Title Auth. Affi. Abst. Keyword ) --Press->

All Technical Committee Conferences  (Searched in: All Years)

Search Results: Conference Papers
 Conference Papers (Available on Advance Programs)  (Sort by: Date Descending)
 Results 1 - 11 of 11  /   
Committee Date Time Place Paper Title / Authors Abstract Paper #
IEICE-MRIS, MMS 2017-10-19
15:10
Niigata Kashiwazaki energy hall, Niigata Micromagnetic analysis of MAMR recording head -- Oscillation of small-sized STO with small external field --
Ryo Itagaki, Yasushi Kanai (Niigata Inst. of Tech.), Simon Greaves, Hiroaki Muraoka (Tohoku Univ.)
A micromagnetic model analysis of a spin-torque oscillator and write head for microwave-assisted magnetic recording was ... [more]
IEICE-MRIS, MMS 2017-06-08
14:55
Miyagi Tohoku Univ. Real Time Observation of Current Driven Magnetic Domains in Magnetic Nanowire Memory by Magneto-optical Microscopy
Mitsunobu Okuda, Mayumi Kawana, Yasuyoshi Miyamoto (NHK)
We have proposed a new magnetic recording memory utilizing parallel aligned nanowires without mechanical moving parts, i... [more] MMS2017-45
pp.11-15
IEICE-MRIS, MMS 2016-06-09
15:20
Miyagi Tohoku Univ. New Magnetic Nanowire Memory utilizing Motion of Magnetic Domains: Formation, Accumulation and Detection of Magnetic Domains in Magnetic Nanowire by Magnetic Recording Head
Mitsunobu Okuda, Yasuyoshi Miyamoto, Mayumi Kawana, Eiichi Miyashita, Nobuo Saito (NHK)
We have proposed the magnetic memories utilizing parallel aligned nanowires without mechanical moving parts, in order to... [more] MMS2016-45
pp.27-31
IEICE-MRIS, MMS 2016-06-10
10:55
Miyagi Tohoku Univ. Simulation of STO for microwave-assisted magnetic recording (3) -- Optimum injected current of integrated STO --
Kazuki Abe, Yuuki Tabuse, Yasushi Kanai (NIIT), kazuetsu Yoshida (Kogakuin Univ.), Simon Greaves, Hiroaki Muraoka (Tohoku Univ.)
Micromagnetic analysis was carried out for the spin-torque oscillator (STO) used for microwave-assisted magnetic recordi... [more]
IEICE-MRIS, MMS 2016-06-10
11:20
Miyagi Tohoku Univ. Micromagnetic simulation of STO for microwave-assisted magnetic recording (4) -- Optimum injected current density of integrated STO vs. write head structure and head material characteristics --
Yuuki Tabuse, Yasushi Kanai (NIIT), Kazuetsu Yoshida (Kogakuin Univ.), Simon Greaves, Hiroaki Muraoka (Tohoku Univ.)
Micromagnetic analysis was carried out for the spin-torque oscillator (STO) used for microwave-assisted magnetic recordi... [more]
IEICE-MRIS, MMS 2015-06-04
14:15
Tokyo Tohoku Univ. Dual free-layer spin-torque oscillator for read head application in magnetic recording
Tazumi Nagasawa, Kiwamu Kudo, Hirofumi Suto, Michinaga Yamagishi, Koichi Mizushima, Rie Sato (Toshiba RDC)
Read heads for HDDs with areal density over 2 Tb/in2 are predicted to suffer from magnetic noises that seriously reduce ... [more]
IEICE-MRIS, MMS 2015-06-04
16:10
Tokyo Tohoku Univ. A Study on Spacing of Barium Ferrite Magnetic Tape Media
Eiki Ozawa, Yuichi Kurihashi, Osamu Shimizu (Recording Media Research Laboratories, FUJIFILM Corporation)
Barium ferrite (BaFe) tape has better write and read-back characteristics due to its small effective head/tape magnetic ... [more]
IEICE-MRIS, MMS 2013-12-13
10:15
Ehime Ehime Univ. Recording field analysis of a magnetic write head for thermally-assisted magnetic recording assuming shingled writing scheme
Hidekazu Tamura, Yasushi Kanai (Niigata Inst. of Tech.), Kiyoshi Yamakawa (AIT), Kazuetsu Yoshida (Kogakuin Univ), Simon Greaves, Hiroaki Muraoka (Tohoku Univ)
Recording field analysis of magnetic recording head in thermally-assisted magnetic recording (TAMR). Static recording fi... [more]
ME, IEICE-BioX 2012-12-12
15:10
Saitama Saitama Inst. of Tech. Examination of Fuzzy Object Model using Brain Segmentation from Newborn Head MR Images
Aya Hashioka (Univ. of Hyogo), Syoji Kobashi, Kei Kuramoto (Univ. of Hyogo/ WPI-IFReC), Yuki Wakata, Kumiko Ando, Reiichi Ishikura (Hyogo College of Medicine), Tomomoto Ishikawa (Ishikawa Hospital), Shozo Hirota (Hyogo College of Medicine), Yutaka Hata (Univ. of Hyogo/ WPI-IFReC)
Neonatal cerebral disorders such as hypoxic-ischemic encephalopathy might deform the brain shape, and reduce patient's c... [more] ME2012-145
pp.65-68
MMS, IEICE-MRIS 2010-06-10
14:00
Miyagi RIEC Tohoku Univ. MR ratio and RA design of CPP-MR film for over 2Tb/in2 read sensors
Masayuki Takagishi, Kenichiro Yamada, Hitoshi Iwasaki, Hiromi Nu Fuke, Susumu Hashimoto (Toshiba)
We estimated the current perpendicular to plane (CPP)-MR performance target required for HDD with areal density from 2Tb... [more]
MMS, IEICE-MRIS 2010-06-10
15:15
Miyagi RIEC Tohoku Univ. Effect of Transition Curvature on Signal Quality for Narrow Track Recording
Masato Shiimoto, Hiroyuki Katada, Yosuke Urakami, Mitsuhiro Hashimoto, Mikito Sugiyama, Takayuki Ichihara, Kazuhiro Nakamoto, Yasutaka Nishida (Hitachi Ltd.)
We investigated the effect of transition curvature on track edge noise through experiments and calculations. We measured... [more]
 Results 1 - 11 of 11  /   
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format


[Return to Top Page]

[Return to ITE Web Page]


The Institute of Image Information and Television Engineers (ITE), Japan