Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
IST |
2020-07-01 15:00 |
Online |
Online |
Evaluation of mosaic multilayer interference filter attached on an image sensor for near-infrared color high-speed fundus camera Masayuki Uemura, Wang Ze, Hironari Takehara (NAIST), Hirofumi Sumi (The Univ. of Tokyo), Hiroyuki Tashiro, Makito Haruta, Kiyotaka Sasagawa, Jun Ohta (NAIST) |
The fundus diagnosis using near-infrared multispectral reduces the patient burden. We fabricated a Fabry-Perot multilaye... [more] |
IST2020-37 pp.19-21 |
IST |
2019-06-18 14:40 |
Tokyo |
Tokyo University of Sci. Morito Kinenkan |
Measurement of gas concentration distribution in vacuum chamber using high SN ratio absorption imaging Keigo Takahashi, Yhang Ricardo Sipauba Carvalho da Silva, Naoki Numao, Rihito Kuroda, Yasuyuki Fujihara, Maasa Murata, Hidekazu Ishii, Tatsuo Morimoto, Tomoyuki Suwa, Akinobu Teramoto, Shigetoshi Sugawa (Tohoku Univ.) |
This paper reports gas concentration absorption imaging in a vacuum chamber using a LOFIC CMOS image sensor with high si... [more] |
IST2019-37 pp.11-14 |
IST |
2018-11-28 16:30 |
Tokyo |
Tamachi Campus, TITECH |
[Poster Presentation]
Multi-band plasmonic color filtering through nanostructured metal thin film for RGB-NIR image sensor Atsutaka Miyamichi, Atsushi Ono, Keiichiro Kagawa, Keita Yasutomi, Shoji Kawahito (Shizuoka Univ.) |
We propose a novel on-chip color filter consisting of periodic corrugated metallic nano-gratings concentrically surround... [more] |
IST2018-60 pp.3-4 |
IST |
2018-11-28 16:30 |
Tokyo |
Tamachi Campus, TITECH |
Development of a mobile multi-spectral compound-eye camera TOMBO Tetsuya Nakanishi (Osaka Univ.), Keiichiro Kagawa (Shizuoka Univ.), Yasuo Masaki (ASAHI E.L.), Jun Tanida (Osaka Univ.) |
An imaging system TOMBO is based on a compound-eye camera whose image sensor is divided by small lenses. It has compact ... [more] |
IST2018-77 pp.37-38 |
IST |
2018-09-25 14:50 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Next-generation Fundus Camera with Full Color Image Acquisition with Advanced NIR Multi-Spectral Imaging System
-- High Speed Vision System and Its Impact on Various Intelligent Applications -- HIrofumi Sumi (UTokyo), Hironari Takehara, Daiki Shirahige, Shunsuke Miyazaki, Kiyotaka Sasagawa, Takashi Tokuda (NAIST), Norimasa Kishi, Yoshihiro Watanabe (UTokyo), Jun Ohta (NAIST), Masatoshi Ishikawa (UTokyo) |
This research describes the development of the next-generation of fundus cameras with a high frame-rate, based on intell... [more] |
IST2018-50 pp.13-16 |
IST |
2018-06-27 13:10 |
Tokyo |
Tokyo Univ. Sci.-Morito-Kinenkan |
[Poster Presentation]
Imaging of Sub-ppm Order Ozonated Water Convection Using High Ultraviolet Light Sensitivity and High Saturation CMOS Image Sensor Maasa Murata, Yasuyuki Fujihara, Yusuke Aoyagi, Rihito Kuroda, Shigetoshi Sugawa (Tohoku Univ.) |
This paper reports ultraviolet (UV) light spectral absorption imaging technology using a high UV light sensitivity and h... [more] |
IST2018-34 pp.13-16 |
IST |
2018-03-09 15:50 |
Tokyo |
NHK Housou-Gijyutu Lab. |
[Invited Talk]
High-image-quality,High-resolution Camera with High Sensitivity up to 1,100nm Takeshi Koyama (Canon) |
Near infrared (NIR) imaging, including spectral imaging, has attracted attention for their potential use in a wide range... [more] |
IST2018-24 pp.55-59 |
IST |
2016-11-17 16:30 |
Tokyo |
TITECH Tamachi Campus |
[Poster Presentation]
190-1100 nm waveband multispectral imaging system using high UV-light resistance 94dB dynamic range CMOS image sensor Yasuyuki Fujihara, Satoshi Nasuno, Shunichi Wakashima, Yusuke Aoyagi, Rihito Kuroda, Shigetoshi Sugawa (Tohoku Univ.) |
A 190-1100nm waveband multispectral imaging system is developed utilizing a highly UV-light sensitive and robust, wide d... [more] |
IST2016-66 pp.37-38 |
IST |
2016-05-06 13:05 |
Tokyo |
|
[Poster Presentation]
Ultraviolet Spectral Imaging using High Light Resistance Wide Dynamic Range CMOS Image Sensor Yasuyuki Fujihara, Satoshi Nasuno, Shunichi Wakashima, Fumiaki Kusuhara, Hidekazu Ishii, Rihito Kuroda, Shigetoshi Sugawa (Tohoku Univ.) |
This paper reports ultraviolet spectral imaging technology using a high light resistance wide dynamic range CMOS image s... [more] |
IST2016-24 pp.13-16 |
IST |
2014-12-01 16:30 |
Tokyo |
Tamachi Campus, Tokyo Institute of Technology |
[Poster Presentation]
A compound-eye imaging module for intraoral biological measurement Hiroki Mima (Osaka Univ.), Keiichiro Kagawa, Atsushi Iwata (Shizuoka Univ.), Chizuko Ogata, Makoto Umeda (Osaka Dental Univ.), Jun Tanida (Osaka Univ.) |
A compound-eye imaging module for intraoral biological measurement is presented. A compound-eye imaging module TOMBO ena... [more] |
IST2014-63 pp.23-24 |
3DMT, IST, IDY |
2012-10-30 14:45 |
Tokyo |
NHK STRL |
Multi-parameter imaging-system based on single-shot phase-shifting digital holography Tatsuki Tahara, Yasunori Ito, Peng Xia, Yasuhiro Awatsuji, Kenzo Nishio, Shogo Ura (KIT), Toshihiro Kubota (Kubota Holography Lab. Corp.), Osamu Matoba (Kobe Univ.) |
Single-shot phase-shifting digital holography is a technique capable of recording three-dimensional (3D) and quantitativ... [more] |
IST2012-56 IDY2012-50 3DIT2012-60 pp.35-38 |
3DMT, IDY, IST |
2010-10-22 14:30 |
Tokyo |
|
[Invited Talk]
Creating 3D cameras based on a compact and thin compound-eye camera TOMBO Keiichiro Kagawa (Osaka Univ), Eiji Tanaka (PED), Kenji Yamada, Jun Tanida (Osaka Univ) |
TOMBO (Thin Observation Module by Bound Optics) is the smallest multi-camera composed of a single image sensor and a len... [more] |
IST2010-57 IDY2010-68 3DIT2010-71 pp.37-40 |